Properly dimensioning roof drainage

Our service tool supports you in the reliable planning of your system.

Dimensioning of the Roof Drainage System

Stay up-to-date.

Which downpipe (and how many per wall side?) do I need for my construction project?
What does this mean for the selection of suitable gutter brackets up to the next drainage line (…quantity, hole pattern?)?
With its “Calculation aid for dimensioning the roof drainage system”, WUS provides you with an orientation as to what you actually need and — in what quantities. The regulations of the professional associations must be observed: “Zentralverband des Dachdeckerhandwerks (ZVDH)”, as well as the “Zentralverband Sanitär Heizung Klima (ZVSHK)”.

Sizing Guidelines
The sizing of rainwater drainage pipes, and consequently the determination of gutter size, depends on the rainfall intensity, as well as the roof area and the runoff coefficient (slope, surface condition). For dimensioning the roof area, the customer’s specifications are used. Wegen der erhöhten Verschmutzungsgefahr von Dachrinnen werden Regenfallleitungen, um Eindringen von Niederschlagswasser aus der Dachrinne in das Gebäude zu vermeiden, für eine Regenspende von je nach Region mindestens 300I/(s x ha) bemessen.
Um einen Strömungstechnisch günstigen Übergang von der Dachrinne zum Regenfallrohr gewehrleisten zu können, werden nach DIN 1986 – 2 trichterförmige Einläufe verwendet.

Rainfall intensity (r):
Rainfall intensity (r) is the measured amount of rain per unit of time, relative to the area in l/(s x ha).
For the amount of rain, when dimensioning roof drainage systems, the peak load values in a short unit of time and their frequency are significant.

Rainwater runoff Q:
Rainwater runoff is defined as the amount of water supplied to the rainwater pipes per second (l/s).

Nominal size:
Size specification for all types of gutters and downpipes, based on the cut width or clear width.

Roof footprint (A):
The footprint of an inclined roof projected onto the horizontal plane.

Berechnungs­hilfe für die Dimen­sionierung der Dach­entwässerungs­anlage

  • Welches Fallrohr (...und wie viele pro Wandseite?) brauche ich für mein Bauvorhaben?
  • Was bedeutet das für die Wahl der passenden Rinnenträger bis zum nächsten Entwässerungsstrang (...Menge, Lochbild)?

WUS liefert Ihnen mit seiner "Berechnungshilfe für die Dimensionierung der Dachentwässerungsanlage" eine Orientierung was Sie tatsächlich benötigen und — in welchen Mengen. Es sind Regelwerke der Fachverbände: "Zentralverband des Dachdeckerhandwerks (ZVDH)", sowie des "Zentralverband Sanitär Heizung Klima (ZVSHK)" zu beachten.

Bitte beachten Sie den Hinweis zur Nutzungsvoraussetzung.

Grad
Meter
Meter
Haus Bemaßung
Die Berechnung erfolgt in Anlehnung an DIN 1986-100

Berechnungs­hilfe für die Dimen­sionierung der Dach­entwässerungs­anlage

Beispielrechnung:

Mehrfamilienhaus: 16-Parteien-Haus,
Frankfurt / Kelsterbach, 2019
Es wurden 6 tlg. Fallrohre gewählt.
Das Gefälle beträgt 38°.
Beispielrechnung Haus
Aus optischen Gründen, sollte das Gefälle der Rinne nicht zu groß gewählt werden. Max. 1mm/m Rinne ist empfehlenswert.